Series MMS-308
Precision in a Threaded Housing
Our MMS 308 series reed sensors in threaded housings offer a reliable solution for industrial applications with threaded bores, ensuring precise switching operations and easy installation.
Do you require a customized solution?
Individual adaptations:
• Dimensions and shape
• Magnetic sensitivity
• Operating temperature
• Connection types
• Housing material
• Mounting / Modification
Areas of application
Position control, non-contact switching
Features
Magnetically operated proximity sensor
Individually defined sensitivity
Customized adjustments possible
Can be operated through non-ferrous materials, e.g., wood, plastic, or aluminum
Series characteristics
Product Information for the Series
The MMS-308 series reed sensors, housed in robust threaded casings, allow for easy screw mounting and are characterized by exceptionally high reliability and flexibility. The series includes various contact forms: normally open (A), normally closed (B), and changeover (C). In addition to variants with low hysteresis, there are also special high-voltage versions designed for up to 1000 V DC. Various cable lengths, sensitivity ranges, and connector options ensure optimal adaptability to individual application conditions in demanding industrial environments.
Dimensions: M12 × L 46.0 mm
Contact Form: A/B/C
Operating Temperature: –20 °C … +80 °C
Sensitivity: 7 … 40 AT
Switching Power: 5 W … 50 W
Switching Current: 0.25 A … 1.0 A
Carry Current: 1.0 A … 3.0 A
Dielectric Strength: 200 VDC … 2000 VDC
Approval
REACH; RoHS
Variant characteristics
Dimensions: M12 × L 46.0 mm
Pitch: 1.5
| MMS-308 -1 | MMS-308 -2 | MMS-308 -3 | MMS-308 -4 | MMS-308 -5 | MMS-308 -9 | MMS-308 -10 | |
|---|---|---|---|---|---|---|---|
| Contact Form | A-Normally Open | A-Normally Open | A-Normally Open | B-Normally Closed | C-Changeover | A-Normally Open | A-Normally Open |
| Operating Temperature | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C |
| Sensitivity | 7 … 30 AT | 15 … 30 AT | 15 … 40 AT | 10 … 35 AT | 10 … 35 AT | 7 … 30 AT | 15 … 35 AT |
| Switching Power | 10 W | 10 W | 50 W | 5 W | 5 W | 10 W | 10 W |
| Switching Current | 0.5 A | 0.4 A | 1.0 A | 0.25 A | 0.25 A | 0.5 A | 0.5 A |
| Switching Voltage VDC | 200 V DC | 200 V DC | 250 V DC | 175 V DC | 175 V DC | 200 V DC | 1000 V DC |
| Switching Voltage VAC | 140 VAC | 265 VAC | 265 VAC | 125 VAC | 125 VAC | 140 VAC | 265 VAC |
| Carry Current | 1.0 A | 1.4 A | 3.0 A | 1.5 A | 1.5 A | 1.0 A | 1.3 A |
| Dielectric Strength | 250 V DC | 400 V DC | 750 V DC | 200 V DC | 200 V DC | 200 V DC | 2000 V DC |
| Small quantities & samples | Please inquire directly | ||||||
| MMS-308 -1 | MMS-308 -2 | MMS-308 -3 | MMS-308 -4 | MMS-308 -5 | MMS-308 -9 | MMS-308 -10 | |
|---|---|---|---|---|---|---|---|
| Contact Form | A-Normally Open | A-Normally Open | A-Normally Open | B-Normally Closed | C-Changeover | A-Normally Open | A-Normally Open |
| Operating Temperature | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C | –20 °C … +80 °C |
| Sensitivity | 7 … 30 AT | 15 … 30 AT | 15 … 40 AT | 10 … 35 AT | 10 … 35 AT | 7 … 30 AT | 15 … 35 AT |
| Switching Power | 10 W | 10 W | 50 W | 5 W | 5 W | 10 W | 10 W |
| Switching Current | 0.5 A | 0.4 A | 1.0 A | 0.25 A | 0.25 A | 0.5 A | 0.5 A |
| Switching Voltage VDC | 200 VDC | 200 VDC | 250 VDC | 175 VDC | 175 VDC | 200 VDC | 1000 VDC |
| Switching Voltage VAC | 140 VAC | 265 VAC | 265 VAC | 125 VAC | 125 VAC | 140 VAC | 265 VAC |
| Carry Current | 1.0 A | 1.4 A | 3.0 A | 1.5 A | 1.5 A | 1.0 A | 1.3 A |
| Dielectric Strength | 250 VDC | 400 VDC | 750 VDC | 200 VDC | 200 VDC | 200 VDC | 2000 VDC |
| Small Quantities & Samples | Please inquire directly | ||||||
◀ Please scroll table sideways ▶
Matching accessories
Actuating magnet

MMA-308